Hydril Pulsation Dampener Manual

  1. High Pressure Pulsation Dampener
  2. Hydril Pulsation Dampener Manual Hydraulic
  • Recommended location for the pulsation control equipment is within 6 times the nominal pipe diameter of the pump discharge manifold. Discharge damp-eners are not effective when installed away from the pump. M20-7500 (Pneumatic Discharge Dampener with Nitrogen Charge) The 20 gallon pneumatic discharge dampener has been the drilling industry.
  • Hydril Type K ' Pulsation Dampener Replacement Diaphragms and Stabilizer for K-10 and K-20 Pulsation Dampeners.
  • Inddition to the ZM pulsation dampener Coorstek offers:. Inline gas-charged pulsation stabilizers. Appendage-type stabilizers. FlowGuard® pulsation dampers. Replacement bladders and repair kits:. Continental Emsco® PD-45, PD-50. Hydril® K-Series, IP-Series ZM-SERIES PULSATION DAMPENER VOLUME ZM-12. 3.9 gallons (14.7 liter).

SFU Series

Manufactured to meet the most demanding large-volume, high-slurry pump applications, Hydril K pulsation dampeners offer outstanding performance for onshore and offshore drilling, airport fueling systems, tank truck and marine loading racks, fire water systems, sewage lines and other large scale pulsation and surge control applications.

  1. SFU o-ring
  2. SFU wing nut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFV & SFVM Series

  1. 6″ or 8″ suction gasket
  2. 6″ or 8″ grooved coupling
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case

SFT Series

  1. HPG-1 gasket (Nitrile or EPDM)
  2. Dust cap
  3. Loading valve
  4. Bleeder valve
  5. Cartridge
  6. Case

SFM Series

  1. SFM o-rings (2 required)
  2. SFM wingnut
  3. Dust cap
  4. Loading valve
  5. Bleeder valve
  6. Cartridge
  7. Case
  8. SFM wingnut screw
Hydril

High Pressure Pulsation Dampener

CHARGE TO 80%- 90% OF SUCTION PRESSURE OR THE MAXIMUM CHARGE PRESSURE OF THE CARTRIDGE, WHICHEVER IS LESS. THIS IS ONLY AN APPROXIMATION.

(YOU MAY FIND IT NECESSARY TO DECREASE THE PRESSURE IN THE SUCTION CARTRIDGE TO ACHIEVE OPTIMUM PUMP PERFORMANCE.)

  1. Shut down pump and relieve line pressure from discharge side before closing suction valve. After discharge line is relieved of pressure, close suction line valve and drain suction line.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY, charge the cartridge through loading valve ’C’ to the recommended operating pressure (90% of suction pressure). (DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE).
  7. Tighten safety nut ’D’ on loading valve ’C’.
  8. Replace loading valve protector cap ’B’
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.
  1. Shut down pump and relieve line pressure.
  2. Open bleeder valve ’A’.
  3. Remove loading valve protector cap ’B’.
  4. Remove cap from loading valve ’C’.
  5. Loosen safety nut ’D’ three full turns.
  6. Using NITROGEN ONLY charge the cartridge through loading valve ’C’ to correct charge pressure (use chart below).
    NOTE: DO NOT EXCEED MAXIMUM CARTRIDGE CHARGE PRESSURE (ON CASE LABEL).
  7. Tighten safety nut ’D’ on loading valve ’C’ and replace cap.
  8. Replace loading valve protector cap ’B’.
  9. Open suction valve. When air from bleeder valve ’A’ is evacuated, close bleeder valve ’A’.

WARNING

THE USE OF ANY GAS OTHER THAN NITROGEN IS EXTREMELY DANGEROUS.

NEVER ATTEMPT TO CHARGE OR PRE-CHARGE A CARTRIDGE OUTSIDE OF THE PULSATION STABILIZER CASE.

FOR PROPER CHARGING PROCEDURES REFER TO THE SUCTION OR DISCHARGE CHARGING GUIDE.

HYDRIL K20 Pulsation Bladders / Dampener and Bladder Kits

IPDTM – PPD (Production Pulsation Dampener Diaphragms

IKDTM – DPD (Drilling Pulsa tion Dampner Diaphragms)

We manufacture and export complete equivalent parts for Hydril dampener (which includes Hydril K20 Pulsation Bladders, Stabiliser Diaphragm, Stabiliser Plate, Lock Washer, Stabiliser Bolt, pulsation dampener charging kit
DescriptionHydril Pulsation Dampener Manual Hydraulic
Location
402 - Kamalalaya center, 156 A-Lenin Sarani,Kolkata-700 013, IndiaEmail: info@rrpcindia.com
Links
Quick Links

© 2019 Rubber Regenerating & Processing Co. Powered By BTN Infosolution